Package Dye Controls
- Functions:
- Heat (with programmable ramp rate.)
- Cool (with programmable ramp rate.)
- Fill (by level, quantity, or ratio.)
- Wash (by time, quantity, ratio.)
- Drain.
- Airpad.
- Chemical add (fast, slow, or dosed from up to two tanks.)
- Operator call.
- Load.
- Unload.
- Sample.
- Safeties:
- High temperature safety cutoff.
- Boiling point temperature safety interlock to airpad system.
- 2 pressure safety interlocks.
- Kier lid closure safety interlocks.
- Multiple user program storage capabilities with complete editing.
- P/I control of analog control loops.
- 16 key membrane key pad.
- 4 line by 20 character backlit LCD display.
- Can operate stand alone or in supervised mode.
- Operator alerted audibly and visually.
- Pneumatic and electronic components housed in a NEMA 12 carbon steel
enclosure.
- Solid state analog inputs.
- Solid state analog outputs.
- Solid state digital inputs.
- Solid state digital outputs.
- RTD temperature measurement.
- Optional Equipment:
- 16 line by 40 character backlit LCD display
- Circular chart recorder